Figure shows the plan and sectional detail of a load bearing residential building. Calculate the quantities of items of work by referring the drawing.

a. UCR Masonry in CM (1:5) - b. 1st class brickwork Masonry in CM (1:4) in super structure - c. 2.5 cm thick DPC (1:2:4) - d. Net quantity of 12 mm thick internal plaster in CM (1:4) -

Mumbai University > CIVIL > Sem 7 > Quantity survey, Estimation and valuation

Marks: 20 M

Year: May 2013

1 Answer
0
5views

Step 1: Total $C_L$ and no. of T junction.

enter image description here

Total C = 2 x 4.8 + 2 x 4 + 2 x 3.8 + 3.5 + 3.7 + 2 x 4 + 1.8 + 2 x 1.9 + 2 x 1.7 + 2.4

= 51.8