Each position corresponds to one of the first 16 modulation symbols. 24 bits from the long code decimator are used for data scrambling in a period of 1.25ms. Only the last four bits of the 24 bits are used to determine the position of the power control bits.
A. Open loop power control: It is implemented on reverse link in which the quality of the signal coming from reference channel of BS is measured by MS. If the strength of the signal coming from BS is above some threshold then the transaction power of the MS is reduced by MS. If the quality of signal reaching to the MS is not good then MS increases its transmission power. Increasing or decreasing the transmission power is done by measuring the quality strength of the signal coming from BS to MS on forward channel. Limitations: In this forward and reverse channels are not correlated. Ms does not know that whether it has minimized the transmission power efficiency or not. There may be delay between signal transmission and reception.
B. Close loop power control: Open loop power control has some limitations and to overcome them the closed loop power control is implemented. Is uses feedback between BS and MS, in this the power of the signal coming from MS is measured by BS and BS send a control signal to tell Ms that what action the MS should perform.