0
1.2kviews
DESIGN OF GRAVITY DAM.
1 Answer
0
8views

The design of a dam has to be economical and at the same time satisfying various requirements of stability. The first step in the design of gravity dam is to decide whether it is low dam or high dam. If the height (H) is within f/w (p + 1). It is a low and is designed as such. Usual dimensions of a low dam are given in Fig. 18.14. for the height of dam exceeding H, it is high dam and is designed as follows:

1. Step by step method: The economical design of a gravity dam by this method envisages division of the dam section in various zones (Fig. 18.15). the successive zones are designed to meet the requirements of stability.

enter image description here

Zone 1: It is the top portion of the dam above maximum reservoir level or above the bottom of ice sheet, if there is ice. If ice pressure exists, the section is checked for sliding. Normally the height of the section is equal to free board provided at the dam. The width is determined by practical consideration or economy for the section as a whole. The upstream and downstream faces are vertical.

Zone 2: The limiting height for the section is the horizontal plane at which (1) The resultant cuts the inner middle third when the reservoir is empty and (2) The resultant cuts the outer third under full reservoir condition. The width is generally more than required and as such both upstream and downstream faces are kept vertical.

Zone 3: The limiting height for this section is the plane at which the resultant under full reservoir condition cuts the outer third. The resultant under empty reservoir condition remains within the inner middle third and as such the upstream face continues to be vertical.

Zone 4: The upstream face also begins to slope in this section to limit the resultant under empty reservoir condition within the inner middle third. The limiting height for the section is determined by the position of the resultant under full reservoir condition so as to limit the stress at downstream tow within the maximum permissible stress.

Zone 5: Usually the maximum permissible stress is reached at the downstream face first and as such the downstream face of the dam. If flattened so as to limit the stress at downstream toe within the maximum permissible stress. In this section, the resultant under full reservoir condition intersects well within the middle third while the resultant under empty reservoir condition intersects at the upstream extremity of the middle third.

Zone 6: In this section, there are maximum pressures at both upstream and downstream faces under reservoir empty and reservoir full condition respectively. The limiting height for the section is the plane at which the inclined pressure at toe just reaches its maximum value. The resultant under reservoir empty and reservoir full condition remains well within the middle third.

Zone 7: With increase in the height of dam, batters of both upstream and downstream faces increase, but at a certain plane the maximum compressive stress at the toe exceeds the working limit. It is desirable to eliminate this section by revising the entire design. Thus the height of the dam is limited to zone 6 by effecting changes in the upper zones by using superior material in zone 6. Fig. 18.16 shows the zoning of masonry in Nagarjunasagar dam.

enter image description here

Please log in to add an answer.