Time delay valve is a combination valve used to set the operation time as per the requirement. The
time delay can be increased or decreased by adjusting the flow through the non-return flow
control valve.
The change invariably increases or decreases the time taken to fill and pilot actuates
the direction control valve. Time delay valve is a combination of a pneumatically actuated 3/2
direction control valve, an air reservoir and a throttle relief valve.
The time delay function is
obtained by controlling the air flow rate to or from the reservoir by using the throttle valve.
Adjustment of throttle valve permits fine control of time delay between minimum and maximum
times. In pneumatic time delay valves, typical time delays in the range 5-30 seconds are possible.
The time delay can be extended with the addition of external reservoir.
Time delay valve, NC type. The constructions of an on-delay timer (NC) type in the normal and
actuated are shown in Figure It can be seen that 3/2 DCV operates in the on delay mode
permanently.
But, in some designs, the valve can be operated in the off-delay mode by connecting
the check valve in reverse direction. For this purpose, the ports of the throttle check valve should be
brought out