Synchronized UJT-Triggering (Ramp Triggering)
1 Answer
4
1.4kviews

Synchronized UJT triggering circuit is shown in Fig. 1. The diode bridge $D_{1}-D_{4}$ rectifies a.c. to d.c. Resistor $R_{s}$ lowers $E_{\text { dc }}$ to a suitable value for the zener diode and UJT. The zener diode $D_{z}$ is used to clip the rectified-voltage to a fixed voltage $V_{z} .$ This voltage $V_{z}$ is applied to the charging circuit $R C .$

Capacitor C Charges through R until it reaches the UJT trigger voltage $V_{p} .$ The UJT then turns "on" and C discharges through the UJT emitter and primary of the pulse- transformer. The windings of the pulse transformer have pulse voltages at their secondary terminals. Pulses at the two secondary windings feed the same inphase pulse to two SCRs of a full wave circuit. SCR with positive anode voltage would turn ON. Rate of rise of capacitor voltage can be controlled by varying R . The firing angle can be controlled up to about $150^{\circ} .$ This method of controlling the output power by varying charging resistor R is called as ramp control, open loop control or manual control.

enter image description here

As the zener diode voltage $V_{z}$ goes to zero at the end of each half cycle, the synchronization of the trigger circuit with the supply voltage across SCRs is achieved. Thus the time time t , equal to $\alpha / \omega,$ when the pulse is applied to SCR for the first time, will remain constant for the same value of R. The various voltage waveforms are shown in Fig.2.

enter image description here